Specifications
| Spectral Range |
Nadir mapper
Nadir profiler
Limb profiler
|
300 380 nm
250 310 nm
290 1000 nm
|
| Spectral Sampling Interval |
Nadir mapper
Nadir profiler
Limb Profiler
|
2.4 pixels per FWHM
2.4 pixels per FWHM
2.0 pixels per FWHM
(Full Width Half Maximum) |
| Spectral Resolution (FWHM) |
Nadir mapper
Nadir profiler
Limb profiler
|
1.0 nm
1.0 nm
1.5 40 nm
|
| Field-of-View (FOV) |
Nadir mapper
Nadir profiler
Limb profiler
|
110 x 0.3 deg
16.7 x 0.3 deg
8.5 x 2.7 deg (3 slits)
|
| Revisit time |
Nadir mapper
Limb profiler
|
24 hours
4 days (average)
|
Mass
Power
Data rate
Size
|
63 kg
60 W
180 kbps
35 x 54 x 56 cm
|
| Total Column EDR |
Horizontal Cell Size:
Measurement Range:
Accuracy:
Precision:
Long-term Stability:
|
50 km at nadir
50-650 Dobson Units (DU)
15 DU or better
3 DU + 0.5% or better
1% over 7 years
|
| Ozone Profile EDR |
Vertical Coverage:
Vertical Cell Size:
Horiz. Cell Size:
Measurement Range:
Accuracy:
Precision:
Long-term Stability:
|
Tropopause 60 km
3 km
250 km
0.1 16 ppmv
10% (15 60 km) 20% (Trop 15 km)
3% (15 50 km) 10% (Trop 15km, 50-60km)
2% over 7 years
|
In addition to providing operational ozone data products, OMPS has the potential to provide other surface and atmospheric science data, including anthropogenic trace gases.
|